Automatic Torque Wrench Calibrator with Window based computer Software
Minimum Order Quantity: 1 Piece
Product Brochure
Model Name/Number | PK - ATWR-2000-S3 |
Usage/Application | Calibration |
Brand | Peak Test |
Range | 2 to 2000 NM |
Automation | Servo Controlled |
Reporting | Using PC Software |
Capacity | 2000 NM |
Country of Origin | Made in India |
Hand torque tool technology and the associated calibration requirements have progressed significantly since the standard was last published in 2003. A number of flaws have also been highlighted within the method described in the previous version which is why a revision was required which resulted in it being divided into two parts:
ISO 6789-1:2017: “Part 1: Requirements and methods for design conformance testing and quality conformance testing: minimum requirements for declaration of conformance” [1]: the method described within is very similar to the previous standard, but the requirement for “certificate of calibration” has been removed and replaced with a requirement for a “declaration of conformance” to ISO 6789-1:2017.
ISO 6789-2:2017: “Part 2: Requirements for calibration and determination of measurement uncertainty” [2]: a significant increase in the number of tool operations. Measurements of the effects of the use of interface adaptors and rotation of the output drive of the tool are all specified and required along with the need to characterize each tool type and record the findings. This has increased the complexity of uncertainty calculation and the result recording application. Without innovation, the new standard significantly increases the time and effort required by an engineer. We encountered various challenges in order to meet the requirements of the new standard whilst maintaining a cost effective service.
Machine capacity |
2000 NM |
Torque Sensors |
3 Nos. (20Nm, 200Nm, 2000Nm) |
Least Count |
0.001Nm / 0.01Nm/ 0.1Nm |
Measuring Units |
Nm, Kgm, Lbft selectable |
Accuracy |
+ 1% of the reading |
Display |
Microcontroller based 6 Digit Digital Display System |
Feature |
Peak hold & Buzzer on Overload |
Software |
Peak Test TWR Calibrator Windows based software |
Power required |
180VAC to 260VAC @ 50 Hz |
Accessories |
Adopters 1/4” to1/2” ¾” 3 Nos |
Calibration & verification for |
Digital, Dial & Click type Mechanism torque wrench, Electric & Pneumatic Screw driver |
Torque applying |
Through Automatic Motor Control |
Calibration |
NABL / NPL Calibrated (Optional) |
Safety |
Overload protection, Emergency Switch |
Warranty |
12 months from the date of installation |